Version: [2.0.3.1855] Last Revised: [03-May-2023] Products: TekScope PC Software Version: 2.0.3.1855 (03-May-2023) New Features: - Waveform Histograms - Waveform Histogram and Measurements - Horizontal and vertical histograms - Draw multiple waveform histogram boxes and accumulate histogram distribution and measurement statistics on Ch/Math/Ref/Rf sources simultaneously - Touch friendly to resize and move the histogram boxes around on the waveform graticule - The following measurements are available for the histogram - Waveform Count, Hits in Box, Peak Hits - Maximum, Minimum, Peak-to-Peak, Mean, Median, Mode - Standard Deviation, One/two/three Sigma - View histogram measurement results in the badge/table format - Waveform histograms supported in history / fast frame mode - Export histograms to the .csv file - Save/Recall waveform tolerance limits as mask files - TekDrive enhancements - Copy/Paste from/to TekDrive file/folder (like local drives) - Support for all Tek files (incl. screencapture/session/setup/waveform files) - Auto increment of files while saving screencaptures/setups/waveforms into TekDrive (like local drives) - Support for all Tek files (incl. screencapture/session/setup/waveform files) - Open In TekScope - Supports session/waveform files - Execute VXI-11 server on app launch - This enables to automate TekScope using NI-VISA/LabView - Show in app Blue Dot Notifier to signal new application version - Show weekly reminder if the application is not upgraded - Math FFT increase the FFT span to 64GHz - NFC – ISO/IEC 15693/14443A standard decode support Defects Fixed: - Fix issue with MSO73300DX scope waveform not visible on connect - Fix continuous acquisitions sequencing issue; sometimes the busy indicator avoids state transitions - Recall the digital source session file - "=" cause an error in report file generation Known Issues: - TekScope can't be installed on multiple logins - If TekDrive folder contains multiple files with same name, on copy/paste from TekDrive to Local - only last downloaded file will remain in the Local folder - work around is to use auto-increment saving the files to TekDrive - Fast frames do not work with non-Starter/Pro/Ultimate Bundle licenses - TekScope can't recall history session file correctly - Unable to use averaging on the Math when using FFT and having cursor gating on Version: [1.44.3.1225] Last Revised: [25-Oct-2022] Products: TekScope PC Software Version: 1.44.3.1225 (25-Oct-2022) New Features: - Base features - Enhanced waveview mask hits feature with consecutive waveform hits. When the Consecutive Failures setting is greater than 1, then the scope tracks consecutive waveform mask hits and reports pass/fail. - Multi Source Cursor Readouts are shown in waveview or on Cursor badge. Configure Cursor Type as Waveform and Cursor Source as “All”. This will display signal voltage and delta cursor values of all active sources - Display Vertical Offset in the waveview channel handles. Configure Channel Offset from the Channel Vertical settings page. This will display the offset (if any) directly in the waveview without opening the Channel context panel - Spectrogram is a visual representation of signal strength over time at various frequencies. - It is a two dimensional graph with third dimension indicating signal strength - Cursor A/B support helps to compare spectrums in up to three different locations on a single source in a single view - Zoom support enables Spectrogram to be drawn for given zoom window in waveview - Color Scale helps to set the colors for Minimum and maximum dB units - New RF Measurements - Channel Power measures the total RF power within the bandwidth defined by the channel width - ACPR measures the signal power leaking from the main channel into adjacent channels upto 5 channels - OBW measures the occupied bandwidth - TekDrive File Storage enhancements - Add/Remove Licenses, SOA mask S/R, Export Log Files and Eye Diagram Plot Panel​ - Single/Multi-Scope support - MSO2000 - Utilities - Export Log Files added for TekScope - Added support for Bookmark Callouts for Remote RF input sources in SpectrumView​ Defects Fixed: - Fix acquire not working on a remote scope when connected with DPO70000 - Fix random crash issues seen with single/multi scopes using VISA connection - Fixed waveform clipping issue reported on Math FFT and fixed waveform rendering issue reported on TDS2000 ​ Known Issues: - None Version: [1.40.3.970] Last Revised: [26-Apr-2022] Products: TekScope PC Software Version: 1.40.3.970 (26-Apr-2022) New Features: - Acquisition Method - Acquisition badge/panel allows to configure Single/Continuous/Sequence acquisition methods - Continuous/Sequence settings will accumulate measurement results - In Continous/Sequence method, any change in TekScope or Remote Scope settings resets the measurement results - Likewise, the acquisition counter - PI Support - Automates multi-scopes to connect and acquire waveform data - Publish Programmer manual - License Expiry Notifiers - About menu shows brief up on selection of each of the license - Red/Gray-dot notifiers indicate if the license options are about to expire or expired - Red/Gray-dot notifiers go off after viewing it atleast once in About menu - Single/Multi-Scope support - MSO 2 Series - MDO 3K support - Installer improvements - Bundle MS-VC redistributables along with the app installer - Remove unwanted PMU/CVP tester files - On app launch if there is a mismatch in Host ID then the app will auto backup the license repository Defects Fixed: - App start up crash issue (because of locale settings vs driver) - Connect MDO3000 via USB or LAN with Starter/Pro License bundles - Connect MDO 3 Series via USB or LAN with Starter/Pro License bundles - Save/Recall app session which includes the .isf waveform file format Known Issues: - On TBS1KC/2KB, app does not import data when the scope’s acquire mode is in peak detect or HiRes. - Sync MSO58B with trigger out of MSO54 has issues Version: [1.38.1.628] Last Revised: [23-Dec-2021] Products: TekScope PC Software Version: 1.38.1.628 (23-Dec-2021) New Features: - Data Logging - Can be configured from Utility -> Act On Event - Users can log Measurements Results Statistics to the CSV files - Additionally save Screen Captures and Waveforms - Live 8-bit Digital data import from 4/5/6-Series MSOs - Improve Setup/Session/Waveform Recall - Double tapping on the Tek files directly from the desktop - On the Windows task bar, drag and drop the Tek file objects to the TekScope application - Retrieve IP Address or Host Names easily using a combobox in Add Scope context panel - Added Firewall screen for Tektronix Myrtille wrapper installer - Source chip format is changed in Measurement badge in RRB - For example: S1_Ch1->1-1, S1_Ch1_D0->1-1D0, S1_svtdm1->1-1M, S1_svtdp1->1-1P and S1_svtdf1->1-1f - Single Remote Connection to below Scope models to pull data in real-time​ - Added Support for the new 5B-Series MSO - TDS2kC - MSO5000, DPO5000 and DPO7000 Defects Fixed: - Long Press stops working after mouse right click on badges Known Issues: - Sometimes with Remote Control On, the waveform imported from TBS2000 scopes show spikes - Changing the Vertical scale to 0.5 V and Record length to 2M show wrong waveform but pressing Single/Seq on the Scope is fixing this issue. - 3-Series MDO is not supported for Starter Bundle License (USB or LAN Connections) - MDO3000 is not supported - TekScope software needs to support DPO/MSO2000 scopes in the Remote Bench Scope Analysis Version: [1.34.8.303] Last Revised: [21-Jun-2021] Products: TekScope PC Software Version: 1.34.8.303 (21-Jun-2021) New Features: - Access Live Full Control of the remote scope - Enhanced tabbed UI for displaying the remote scopes (removes the dependency on browser) - Supports for both Linux and Windows based scopes - Remote connection to MDO 3 Series Support - Spectrum View I/Q data import - Update the Horizontal Badge width in remote control mode - Installer updates - Update Firewall settings through TekScope installer - Note highlighting the current Win-10 Update version - Myrtille wrapper installer package downloadable for Windows scopes Defects Fixed: - The bandwidth limit for remote 70K scope should be more than 8 Ghz - Deskew maximum limit should increase in tekscope - Recalling Spectrum View Span correctly (based on what is saved in setup) - Recalling Fast Frame with multi frames allows to navigate - FRA plot doesn't show up in TekScope PC Known Issues: - Act On Event does not work as expected (currently disabled) Version: [1.32.2.828] Last Revised: [05-Feb-2021] Products: TekScope PC Software Version: 1.32.2.828 (05-Feb-2021) New Features: - TekDrive file storage - Mount/unmount the TekDrives - QR Code authentication to connect to TekDrives - Save/Recall Waveform, Setup, Report, Session, Mask to/from TekDrives - Save Screen Capture, and Table Data to TekDrives - File Utilities - Copy/Paste of Files/Folders - Refresh Waveforms is added as a short-cut to the right-click menu of the Scope badge Defects Fixed: - TekScope imports/syncs with Basic Scope Channel Vertical Position - Fast Frame badge shows up on session/setup recall - Advanced Clock Recovery Nominal Data Rate Bit Rate Max limit is updated with double.max() - Trigger Edge Level Min/Max limit is updated with +/- 10 kV Known Issues: - Sometimes the sampling mode IT indicator is shown in the Horizontal badge - Sometimes TekDrives cannot be unmounted when the wireless LAN connection is restored (work around is to restart TekScope and then unmount) Version: [1.30.3.731] Last Revised: [04-Nov-2020] Products: TekScope PC Software Version: 1.30.3.731 (04-Nov-2020) New Features: - Multi-Scope Analysis [phase 2]:​ - Support 4 scopes / 32 channels​ - Brand new user interface - Remote connection to MSO/DPO 70000 (C/SX/DX) Support [in addition to 4/5/6 Series MSO] - USB Interface for Remote Connection [in addition to Ethernet] - Data Transfer Time Improvements – up to 16x! - View/Configure remote scopes using e*Scope or MS-Remote Desktop Connection for Linux or Windows based oscilloscopes respectively ​ - New License Option - Remote Analysis for Bench Oscilloscopes: - Single Remote Connection to Bench Oscilloscopes (TBS1000,TBS2000) to pull data in real-time​ - Essential Protocol Decoders: I2C, SPI, UART, CAN, CANFD, LIN, SENT and I3C Decoding​ - Remote Connection Interface – USB and Ethernet - New Perpetual Licenses: - Removal of 3-yr license options - Addition of perpetual license options (indefinite use of the software, maintenance for first 12 months) - Boxcar 12 Integration: - Exclusions: Frequency Response Analysis, Mask Testing. Defects Fixed: - Improve the trigger time skew between two remote scope slaves - Refined the I/O UI to configure Remote Control - Measurement/Search previous/next navigation associated with remote channels is supported - Waveform recall of .csv file type generated from TDS/TBS/TPS 1000/2000 is supported Known Issues: - Measurement Results table do not reset the accumulated statistics - Waveforms are not rendered when the horizontal delay is set On and the delay time is over 1 sec - No feedback shown in the UI if some trigger/horizontal settings fail to set - Translations for different language settings do not work fully - Sometimes the remote channel badge does not appear but after adding a new source it recovers